JOM KITA KE POLITEKNIK

Direct Signal Control of the Steady-State Response of 3D-FSE Sequences (Record no. 920)

MARC details
042 ## - AUTHENTICATION CODE
Authentication code dc
100 10 - MAIN ENTRY--PERSONAL NAME
Personal name Malik, Shaihan J.
Relator term author
9 (RLIN) 1901
245 00 - TITLE STATEMENT
Title Direct Signal Control of the Steady-State Response of 3D-FSE Sequences
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Date of publication, distribution, etc. 2015-03-01.
500 ## - GENERAL NOTE
General note /pmc/articles/PMC7614097/
500 ## - GENERAL NOTE
General note /pubmed/24639096
520 ## - SUMMARY, ETC.
Summary, etc. PURPOSE: Parallel transmission (PTx) offers spatial control of radiofrequency (RF) fields that can be used to mitigate nonuniformity effects in high-field MRI. In practice, the ability to achieve uniform RF fields by static shimming is limited by the typically small number of channels. Thus, tailored RF pulses that mix gradient with RF encoding have been proposed. A complementary approach termed "Direct Signal Control" (DSC) is to dynamically update RF shims throughout a sequence, exploiting interactions between each pulse and the spin system to achieve uniform signal properties from potentially nonuniform fields. This work applied DSC to T2-weighted driven-equilibrium three-dimensional fast spin echo (3D-FSE) brain imaging at 3T. THEORY AND METHODS: The DSC concept requires an accurate signal model, provided by extending the spatially resolved extended phase graph framework to include the steady-state response of driven-equilibrium sequences. An 8-channel PTx body coil was used for experiments. RESULTS: Phantom experiments showed the model to be accurate to within 0.3% (root mean square error). In vivo imaging showed over two-fold improvement in signal homogeneity compared with quadrature excitation. Although the nonlinear optimization cannot guarantee a global optimum, significantly improved local solutions were found. CONCLUSION: DSC has been demonstrated for 3D-FSE brain imaging at 3T. The concept is generally applicable to higher field strengths and other anatomies. Magn Reson Med 73:951-963, 2015. © 2014 Wiley Periodicals, Inc.
540 ## - TERMS GOVERNING USE AND REPRODUCTION NOTE
Terms governing use and reproduction
546 ## - LANGUAGE NOTE
Language note en
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element Article
655 7# - INDEX TERM--GENRE/FORM
Genre/form data or focus term Text
Source of term local
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Beqiri, Arian
Relator term author
9 (RLIN) 2470
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Padormo, Francesco
Relator term author
9 (RLIN) 2471
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Hajnal, Joseph V.
Relator term author
786 0# - DATA SOURCE ENTRY
Note Magn Reson Med
856 41 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://dx.doi.org/10.1002/mrm.25192">http://dx.doi.org/10.1002/mrm.25192</a>
Public note Connect to this object online.

No items available.