JOM KITA KE POLITEKNIK

Retest reliability for complete airway interruption systems of aerodynamic measurement (Record no. 260)

MARC details
042 ## - AUTHENTICATION CODE
Authentication code dc
100 10 - MAIN ENTRY--PERSONAL NAME
Personal name Lamb, Jim R.
Relator term author
9 (RLIN) 954
245 00 - TITLE STATEMENT
Title Retest reliability for complete airway interruption systems of aerodynamic measurement
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Date of publication, distribution, etc. 2020-04-04.
500 ## - GENERAL NOTE
General note /pmc/articles/PMC7541393/
500 ## - GENERAL NOTE
General note /pubmed/32253079
520 ## - SUMMARY, ETC.
Summary, etc. INTRODUCTION: Measures of subglottal pressure (Ps), phonation threshold pressure (PTP), and laryngeal resistance (LR) can be used as indicators of vocal cord disorders. The gold standard non-invasive measurement uses labial interruption, which has been shown to have reliability inconsistencies. Mechanical interruption methods have demonstrated promise in measurement reliability. The goal of the present study is to compare retest reliability of labial and mechanical interruption methods. METHODS: 55 subjects aged 18-69 participated. 10 trials were performed for each method. For labial interruption, subjects produced five labial plosives at comfortable and quiet volumes. For mechanical interruption, subjects produced a sustained /α/ while a balloon valve interrupted phonation five times. 30 subjects completed a second study visit identical to the first approximately two weeks (15 days ± 3.76) after the first visit. Ps, PTP, mean airflow rate (MFR), and LR were determined for each subject and retest reliability for each was analyzed. RESULTS: The percent difference in measurement results for test-retest of Ps were 12.88% ± 10.15 for mechanical interruption and 27.56% ± 17.14 for labial interruption (p = 0.0003). The percent difference for PTP measurements were 21.46% ± 16.01 for mechanical and 17.04% ± 14.62 (p = 0.3372) for labial. Intra-subject coefficients of variation of Ps were 0.086 ± 0.046 for mechanical and 0.161 ± 0.078 for labial (p < 0.0001). For PTP, the coefficients were 0.177 ± 0.083 for mechanical and 0.186 ± 0.091 for labial (p = 0.5402). Lastly, for LR (Ps divided by MFR) the percent differences were 14.33% ± 10.06 for mechanical and 53.87% ± 43.19 for labial (p < 0.0001) with intra-subject variability of 0.115 ± 0.050 for mechanical and 0.287 ± 0.222 for labial (p < 0.0001). CONCLUSIONS: Ps and LR measured using mechanical interruption showed more consistency for both retesting across separate study visits and intra-subject variability. PTP was similar in retesting and intra-subject variability. Continued work to improve mechanical interruption techniques is warranted as these methods offer higher reliability and consistency than the labial interruption methods.
540 ## - TERMS GOVERNING USE AND REPRODUCTION NOTE
Terms governing use and reproduction
546 ## - LANGUAGE NOTE
Language note en
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
Topical term or geographic name as entry element Article
655 7# - INDEX TERM--GENRE/FORM
Genre/form data or focus term Text
Source of term local
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Schultz, Sarah A.
Relator term author
9 (RLIN) 955
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Scholp, Austin J.
Relator term author
9 (RLIN) 956
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Wendel, Emily R.
Relator term author
9 (RLIN) 957
700 10 - ADDED ENTRY--PERSONAL NAME
Personal name Jiang, Jack J.
Relator term author
9 (RLIN) 958
786 0# - DATA SOURCE ENTRY
Note J Voice
856 41 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://dx.doi.org/10.1016/j.jvoice.2020.02.024">http://dx.doi.org/10.1016/j.jvoice.2020.02.024</a>
Public note Connect to this object online.

No items available.